Coil wires
Coil wires
ПЭТД – 180
Area of application: ПЭТД – 180 type coil wire is specified for use in communication apparatuses, relays, meters, measuring devices, generatrs, engines, industrial and domestic appliances and dry type transformers.
1. Circular copper wire
2. 2nd type polyether amide varnish insulation
3. 2nd type polyamideimide varnish insulation
ПЭТВ – 1, ПЭТВ – 2
Area of application:: ПЭТВ type coil wire is specified for use in electric transformers filled with oil, low capacity engines, telephone capsules, recorders (printing machines, recording devices, etc.) and measuring devices.
1. Circular copper wire
2. 1st type diluted polyether varnish insulation
ПЭТД 200 – 1, ПЭТД 200 – 2
Area of application:: ПЭТД 200 type coil wire is specified for use in communication apparatuses, relays, meters, measuring devices, generatrs, engines, industrial and domestic appliances and dry type transformers.
1. Circular copper wire
2. 1st type polyether amide varnish insulation
3. 1st type polyamideimide varnish insulation
ПЭТ – 155
Area of application:: ПЭТ – 155 type coil wire is specified for use in meters and relays, measuring devices, dry type transformers, generators, domestic electrical devices and tools, multipurpose power engines.
1. Circular copper wire
2. 1st type polyether amide varnish insulation
Texniki göstəricilər:
Parameters
Wire diameter, mm | Wire design weight, kg/km |
---|---|
0,630 | 2,86 |
0,670 | 3,23 |
0,690 | 3,42 |
0,710 | 3,62 |
0,750 | 3,04 |
0,800 | 4,59 |
0,850 | 5,18 |
0,900 | 5,80 |
0,950 | 6,47 |
1,000 | 7,16 |
1,060 | 8,04 |
1,120 | 8,96 |
1,180 | 9,94 |
Parameters
Wire diameter, mm | Wire design weight, kg/km |
---|---|
1,200 | 10,27 |
1,250 | 11,14 |
1,320 | 12,42 |
1,400 | 13,96 |
1,500 | 16,01 |
1,600 | 18,20 |
1,700 | 20,52 |
1,800 | 22,99 |
1,900 | 25,61 |
2,000 | 28,35 |
2,120 | 31,85 |
2,240 | 35,53 |
2,360 | 39,41 |
2,500 | 44,19 |
Parameters
Wire type | ПЭТД-180 | ПЭТВ–1 | ПЭТВ–2 | ПЭТВ 200–1 | ПЭТВ 200–2 | ПЭТ–155 |
---|---|---|---|---|---|---|
Temperature index* | 180 | 130 | 130 | 200 | 200 | 155 |
Wire diameter, mm | 0,63 - 2,5 | 0,63 - 4,00 | 0,63-4,00 | 0,63-4,00 | 0,63-4,00 | 0,63-2,5 |
- Maximum operating temperature, °C: 155, 180, 200
- Minimum operating temperature: -60°C
- Service life: 30 years
Installation wires for water submersible electric motors ВПП, ВППУ, ВПВ
Area of application: Wires are intended for connection to the grid of submersible electric motors for a rated voltage of 380, 660 and 3000 V AC at 50 Hz frequncy continuously operating in the water of artesian wells: pressurized up to 7,09•106 Pa (70kgf/cm2) at ambient temperature from -40 to +65 ⁰C (ВПП wire); at a pressure of more than 1,7•107 Pa (150 kgf/cm2) at a temperature from -40 to +80 ⁰ C (ВППУ wire).
Area of application::
Warranty period of operation is 2.5 years from the date the wires put into operation. Service life: 6 years.
Сonstruction:
1. Conductor: Copper.
2. Insulation: Polyethylene
3. Sheath: polyvinylchloride or polyethylene
Parameters
Nominal cross-section area, mm | Rated operation voltage, V | ||
---|---|---|---|
380 | 660 | 3000 | |
Wire diameter, mm | |||
1,5 | 5,61 | 5,83 | - |
2,5 | 6,12 | 6,34 | - |
4 | 6,89 | 7,11 | - |
6 | 7,48 | 7,7 | - |
10 | 8,63 | 9,76 | - |
16 | 10,4 | 10,8 | - |
25 | 12,5 | 12,9 | 13 |
35 | 13,4 | 13,8 | 14 |
50 | 15,1 | 15,5 | - |
70 | 16,9 | 17,3 | - |
Coil wires for water submersible electric motors ПВДП, ПЭВВП
Area of application: Wires are used for stator windings water filled submersible Electric motor continuously operating in the water boreholes at voltages up to 660 V AC, 40-60 Hz.
Texniki göstəricilər:
Operating temperature range from -50°C to +80°C
Warranty period of operation is 2.5 years since wires put into operation.
Service life: 6 years.
Сonstruction:
1. Conductor: Copper.
2. Insulation - from high pressure polyethylene.
3. Sheath - from low pressure polyethylene.
Parameters
Wire diameter, mm | Wire design weight, kg/km |
---|---|
1,40 | 16,0 |
1,60 | 20,5 |
1,80 | 26,0 |
2,00 | 31,5 |
2,12 | 36,0 |
2,36 | 44,0 |
2,50 | 49,0 |
2,80 | 60,5 |
3,18 | 63,5 |
Parameters
Wire diameter, mm | Wire design weight, kg/km |
---|---|
3,54 | 77,5 |
3,75 | 86,5 |
3,96 | 96,0 |
4,50 | 122,0 |
4,80 | 138,0 |
5,30 | 165,5 |
5,90 | 203,5 |
6,25 | 227,5 |