Control cables

NYY, NYY-fl, NYY-LS, NAYY, NAYY-fl, NAYY-LS


Area of application:
NYY, NYY-fl, NYY-LS, NAYY, NAYY-fl, NAYY-LS type control cables are used during stationary installation in electrical appliances, alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V, confined spaces, channels, tunnels, aggressive environment, areas under external mechanical effects.

Сonstruction:
1. Copper or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PET tape band insulation
4. PVC sheath (flame-retardant, low smoke and gas emitting PVC)

plastcongroup.az

Technical parameters:
  • Rated operation voltage: 660 V
  • Core lateral section mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
  • Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
  • Relative air humidity: 98% at 35°C temperature
  • Ambient temperature during use of wire: -50°C +50°C
  • Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 1,0 85,3 18,1
5 х 1,0 112,5
7 х 1,0 142
10 х 1,0 196
14 х 1,0 255,1
19 х 1,0 329,2
27 х 1,0 451,7
37 х 1,0 610,7
4 х 1,5 118 12,1
5 х 1,5 141,7
7 х 1,5 182,7
10 х 1,5 253,4
14 х 1,5 332,2
19 х 1,5 432,3
27 х 1,5 612
37 х 1,5 809,3

plastcongroup.az

Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 2,5 164,3 7,41
5 х 2,5 197,6
7 х 2,5 259
10 х 2,5 362,1
14 х 2,5 481,4
19 х 2,5 632,4
27 х 2,5 896,7
37 х 2,5 1214,5
4 х 4,0 238,1 4,61
7 х 4,0 383,1
10 х 4,0 538,1
4 х 6,0 323,5 3,08
7 х 6,0 528,3
10 х 6,0 761,1

plastcongroup.az


Shielded Control cables

NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS


Area of application:
NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS type control cables are used during stationary installation in electrical appliances, alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V, confined spaces, channels, tunnels, aggressive environment, areas under external mechanical effects and for hindering intervention of outside electromagnetic waves. Cable cores are twisted in layers and each layer contains two varicolored cores, which differ from the color of other cores and/or are numbered.

Сonstruction:
1. Copper or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PVC and/or PET tape band insulation
4. Copper and/or aluminum tape (foil) shielding
5. Under shield copper wire
6. PVC sheath (flame-retardant, low smoke and gas emitting PVC)

plastcongroup.az

Technical parameters:
  • Rated operation voltage: 660 V
  • Core lateral section mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
  • Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
  • Relative air humidity: 98% at 35°C temperature
  • Ambient temperature during use of wire:-50°C +50°C
  • Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 1,0 116,3 18,1
5 х 1,0 135
7 х 1,0 166,8
10 х 1,0 225,5
14 х 1,0 285,8
19 х 1,0 362,7
27 х 1,0 505,8
37 х 1,0 655,4
4 х 1,5 141,3 12,1
5 х 1,5 165,5
7 х 1,5 208,1
10 х 1,5 283,9
14 х 1,5 365,2
19 х 1,5 468,4
27 х 1,5 655,8
37 х 1,5 857,6
Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 2,5 188,4 7,41
5 х 2,5 223,6
7 х 2,5 286,9
10 х 2,5 395,9
14 х 2,5 518
19 х 2,5 688,2
27 х 2,5 945,6
37 х 2,5 1270,4
4 х 4,0 265,7 4,61
7 х 4,0 415
10 х 4,0 593,2
4 х 6,0 353,5 3,08
7 х 6,0 563,6

plastcongroup.az


Armored Control cables

NYBY, NYBY-fl, NYBY-LS, NAYBY, NAYBY-fl, NAYBY-LS


Area of application:
NYBY, NYBY-fl, NYBY-LS, NAYBY, NAYBY-fl, NAYBY-LS type control cables are used during stationary installation in electrical appliances, alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V, confined spaces, channels, tunnels, aggressive environment, areas under external mechanical effects. Cable cores are twisted in layers and each layer contains two varicolored cores, which differ from the color of other cores and/or are numbered.

Сonstruction:
1. Copper and/or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PVC band insulated
4. Double galvanized steel tape armor
5. PVC sheath (flame-retardant, low smoke and gas emitting PVC)

plastcongroup.az

Technical parameters:
  • Rated operation voltage: 660 V
  • Core lateral section mm²: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
  • Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
  • Relative air humidity: 98% at 35°C temperature
  • Ambient temperature during use of wire:-50°C +50°C
  • Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 1,0 116,3 18,1
5 х 1,0 135
7 х 1,0 166,8
10 х 1,0 225,5
14 х 1,0 285,8
19 х 1,0 362,7
27 х 1,0 505,8
37 х 1,0 655,4
4 х 1,5 141,3 12,1
5 х 1,5 165,5
7 х 1,5 208,1
10 х 1,5 283,9
14 х 1,5 365,2
19 х 1,5 468,4
27 х 1,5 655,8
37 х 1,5 857,6

plastcongroup.az

Parameters
Number and lateral section of cores pcs x mm2 Wire design weight, kg/km R for cooper cable
4 х 2,5 188,4 7,41
5 х 2,5 223,6
7 х 2,5 286,9
10 х 2,5 395,9
14 х 2,5 518
19 х 2,5 688,2
27 х 2,5 945,6
37 х 2,5 1270,4
4 х 4,0 265,7 4,61
7 х 4,0 415
10 х 4,0 593,2
4 х 6,0 353,5 3,08
7 х 6,0 563,6

plastcongroup.az