Control cables
NYY, NYY-fl, NYY-LS, NAYY, NAYY-fl, NAYY-LS
Area of application:
NYY, NYY-fl, NYY-LS, NAYY, NAYY-fl, NAYY-LS type control cables are used during stationary installation in electrical appliances,
alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V,
confined spaces, channels, tunnels, aggressive environment, areas under external mechanical effects.
Сonstruction:
1. Copper or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PET tape band insulation
4. PVC sheath (flame-retardant, low smoke and gas emitting PVC)
- Rated operation voltage: 660 V
- Core lateral section mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
- Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
- Relative air humidity: 98% at 35°C temperature
- Ambient temperature during use of wire: -50°C +50°C
- Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 1,0 | 85,3 | 18,1 |
5 х 1,0 | 112,5 | |
7 х 1,0 | 142 | |
10 х 1,0 | 196 | |
14 х 1,0 | 255,1 | |
19 х 1,0 | 329,2 | |
27 х 1,0 | 451,7 | |
37 х 1,0 | 610,7 | |
4 х 1,5 | 118 | 12,1 |
5 х 1,5 | 141,7 | |
7 х 1,5 | 182,7 | |
10 х 1,5 | 253,4 | |
14 х 1,5 | 332,2 | |
19 х 1,5 | 432,3 | |
27 х 1,5 | 612 | |
37 х 1,5 | 809,3 |
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 2,5 | 164,3 | 7,41 |
5 х 2,5 | 197,6 | |
7 х 2,5 | 259 | |
10 х 2,5 | 362,1 | |
14 х 2,5 | 481,4 | |
19 х 2,5 | 632,4 | |
27 х 2,5 | 896,7 | |
37 х 2,5 | 1214,5 | |
4 х 4,0 | 238,1 | 4,61 |
7 х 4,0 | 383,1 | |
10 х 4,0 | 538,1 | |
4 х 6,0 | 323,5 | 3,08 |
7 х 6,0 | 528,3 | |
10 х 6,0 | 761,1 |
Shielded Control cables
NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS
Area of application:
NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS type control cables are used during stationary installation in electrical appliances,
alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V,
confined spaces, channels, tunnels, aggressive environment, areas under external mechanical effects and for hindering intervention
of outside electromagnetic waves. Cable cores are twisted in layers and each layer contains two varicolored cores,
which differ from the color of other cores and/or are numbered.
Сonstruction:
1. Copper or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PVC and/or PET tape band insulation
4. Copper and/or aluminum tape (foil) shielding
5. Under shield copper wire
6. PVC sheath (flame-retardant, low smoke and gas emitting PVC)
- Rated operation voltage: 660 V
- Core lateral section mm2: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
- Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
- Relative air humidity: 98% at 35°C temperature
- Ambient temperature during use of wire:-50°C +50°C
- Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 1,0 | 116,3 | 18,1 |
5 х 1,0 | 135 | |
7 х 1,0 | 166,8 | |
10 х 1,0 | 225,5 | |
14 х 1,0 | 285,8 | |
19 х 1,0 | 362,7 | |
27 х 1,0 | 505,8 | |
37 х 1,0 | 655,4 | |
4 х 1,5 | 141,3 | 12,1 |
5 х 1,5 | 165,5 | |
7 х 1,5 | 208,1 | |
10 х 1,5 | 283,9 | |
14 х 1,5 | 365,2 | |
19 х 1,5 | 468,4 | |
27 х 1,5 | 655,8 | |
37 х 1,5 | 857,6 |
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 2,5 | 188,4 | 7,41 |
5 х 2,5 | 223,6 | |
7 х 2,5 | 286,9 | |
10 х 2,5 | 395,9 | |
14 х 2,5 | 518 | |
19 х 2,5 | 688,2 | |
27 х 2,5 | 945,6 | |
37 х 2,5 | 1270,4 | |
4 х 4,0 | 265,7 | 4,61 |
7 х 4,0 | 415 | |
10 х 4,0 | 593,2 | |
4 х 6,0 | 353,5 | 3,08 |
7 х 6,0 | 563,6 |
Armored Control cables
NYBY, NYBY-fl, NYBY-LS, NAYBY, NAYBY-fl, NAYBY-LS
Area of application:
NYBY, NYBY-fl, NYBY-LS, NAYBY, NAYBY-fl, NAYBY-LS type control cables are used during stationary installation in electrical appliances,
alternating-current equipment with nominal voltage of 660 V and/or direct-current switchgears with nominal voltage of up to 1000 V, confined spaces,
channels, tunnels, aggressive environment, areas under external mechanical effects.
Cable cores are twisted in layers and each layer contains two varicolored cores, which differ from the color of other cores and/or are numbered.
Сonstruction:
1. Copper and/or aluminum wire core
2. PVC insulation (flame-retardant, low smoke and gas emitting PVC)
3. PVC band insulated
4. Double galvanized steel tape armor
5. PVC sheath (flame-retardant, low smoke and gas emitting PVC)
- Rated operation voltage: 660 V
- Core lateral section mm²: 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10.0
- Number of cores: 4, 5, 7, 10, 14, 19, 27, 37, 61
- Relative air humidity: 98% at 35°C temperature
- Ambient temperature during use of wire:-50°C +50°C
- Service life: underground and in trestleworks – 15 years, in confined spaces, canals and tunnels - 25 years
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 1,0 | 116,3 | 18,1 |
5 х 1,0 | 135 | |
7 х 1,0 | 166,8 | |
10 х 1,0 | 225,5 | |
14 х 1,0 | 285,8 | |
19 х 1,0 | 362,7 | |
27 х 1,0 | 505,8 | |
37 х 1,0 | 655,4 | |
4 х 1,5 | 141,3 | 12,1 |
5 х 1,5 | 165,5 | |
7 х 1,5 | 208,1 | |
10 х 1,5 | 283,9 | |
14 х 1,5 | 365,2 | |
19 х 1,5 | 468,4 | |
27 х 1,5 | 655,8 | |
37 х 1,5 | 857,6 |
Number and lateral section of cores pcs x mm2 | Wire design weight, kg/km | R for cooper cable |
---|---|---|
4 х 2,5 | 188,4 | 7,41 |
5 х 2,5 | 223,6 | |
7 х 2,5 | 286,9 | |
10 х 2,5 | 395,9 | |
14 х 2,5 | 518 | |
19 х 2,5 | 688,2 | |
27 х 2,5 | 945,6 | |
37 х 2,5 | 1270,4 | |
4 х 4,0 | 265,7 | 4,61 |
7 х 4,0 | 415 | |
10 х 4,0 | 593,2 | |
4 х 6,0 | 353,5 | 3,08 |
7 х 6,0 | 563,6 |